Brand Name : Daruifuno

Model Number : AEC1-C2A

Certification : CE

Place of Origin : China

MOQ : Negotiable

Price : Negotiable

Product Name : Conductivity Analyzer

Product Model : AEC1-C2A

Conductivity Resolution : 0.001µS /cm

Conductivity Range : 0.00~10.00 mS/cm

Relay Control : 2 SPST relays

Communication Method : RS485

Display Screen : 128*64 LCD screen

Protection Grade : IP66

Dimension : 100*100*120 mm

Power Supply : 100~240V AC

Contact Now

 

Online Conductivity Analyzer 2 SPST For Waste Water Treatment 100 * 100 * 120mm

 

 

Introduction

 

The online conductivity analyzer uses electrode measurement method to realize the continuously monitoring of the conductivity value in the solution. The AEC1-C2A conductivity controller can be connected with DRFN’s conductivity sensors with different cell constants to achieve different measurement ranges. This model has a conductivity measurement range of 0.00~10.00mS/cm.
 
 
Advantages Of The Online Conductivity Analyzer
 
2-electrode measurement method
 
IP66 protection grade
 
2 SPST multi-function relays
 
2 high-precision 0/4~20mA current output
 
A two-wire RS485 interface
 
128*64 large graphic dot matrix LCD screen
 
shortcut keys to carry out daily necessary maintenance
 
 
2 SPST Online Conductivity Meter For Waste Water Treatment 100 X 100 X 120mm
 
 
Applications Of The Online Conductivity Analyzer
 
● Power plant-water treatment;
 
● Water plants and sewage plants-wastewater treatment;
 
● Papermaking-production process/wastewater treatment;
 
● Chemical oil refining-production process/wastewater treatment;
 
● Metallurgy and mining-production process/wastewater treatment;
 
● Food and beverage-production process/wastewater treatment;
 
● Pharmaceutical industry-biological reaction and fermentation/wastewater treatment;
 
● Semiconductor-production process/waste water treatment/high-purity water production.
 
 

Technical Parameters
 

Product Name

Conductivity analyzer

Product Model

AEC1-C2A

Software Version

DRFN conductivity Analysis software V1.0

Conductivity Measuring Range

0.00~10.00 mS/cm, full range automatic switching (The measurement range is related to the connected electrode constant)

Temperature Measuring Range

-10~150℃ /14~302℉

Resistivity Display Range

0.01Ω.cm~18MΩ.cm

TDS Display Range

0.000mg/L~500g/L

Salinity Display Range

(0.00~10.0)%

Conductivity Resolution

0.001μS/cm

Resistivity Resolution

0.01Ω.cm

TDS Resolution

0.001mg/L

Salinity Resolution

0.01%

Temperature Resolution

0.1℃/ 0.1℉

Accuracy

0.1% of measuring range

Stability

0.05% of the measuring range every 24 hours, no accumulation

Repeatability

Better than 0.1% of the measuring range

Sensor Diagnosis

Screen image display

Relay Control

2 settable SPST relays max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface, MODBUS RTU

Display Screen

128*64 LCD, adjustable backlight mode

Configuration Information

Power failure protection, indefinite retention of parameters

Protection Level

IP66

Operating Environment

0~60℃, relative humidity less than 95%

Storage Environment

-20~70℃, relative humidity less than 55%

Shell Material

Enhanced ABS

Dimensions

100*100*120mm (hole size 92*92 mm)

Mounting Method

panel mounting

Electrical Interface

Three M12*1.5 Gellen heads are reserved at the back of the instrument, with a wire diameter of 3~6.5mm.

Power Supply

100~240V AC

Weight

500g

Power Consumption

3W

 
 
Recommended Conductivity Sensors 
 

Model Measuring Method K-value Measuring Range Temperature Compensation
ASC100 Graphite 2-pole electrode 1 0~20000μS/cm No
ASC200 Graphite 2-pole electrode 1 0~20000μS/cm PT or NTC
ASC400 Planar 4-pole electrode 0.5 0~200000μS/cm No
ASCK1 2-pole conductivity cell electrode 1 1~2000μS/cm PT or NTC
ASCK01 2-pole conductivity cell electrode 0.1 0.1~200μS/cm PT or NTC
ASCK001 2-pole conductivity cell electrode 0.01 0.01~20μS/cm PT or NTC

 
 
 


Product Tags:

100mm online conductivity meter

      

2 SPST digital conductivity meter

      

120mm online conductivity meter

      
Buy cheap 2 SPST Online Conductivity Meter For Waste Water Treatment 100 X 100 X 120mm product

2 SPST Online Conductivity Meter For Waste Water Treatment 100 X 100 X 120mm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)